Microbial control methods — A/L Biology

Aligned with the NIE syllabus

How do I practise Microbial control methods?

1 question with a worked solution

  1. Which operating parameters are standardly prescribed for routine autoclaving to ensure total destruction of resistant bacterial endospores (such as Geobacillus stearothermophilus)?
    1. A) 72 °C for 15 seconds followed by rapid chilling
    2. B) 160 °C in a dry-air oven for 30 minutes
    3. C) 100 °C at atmospheric pressure for 10 minutes
    4. D) 121 °C at 15 psi (103 kPa) pure steam pressure for 15–20 minutes
    Check my answer

    Correct answer: D) 121 °C at 15 psi (103 kPa) pure steam pressure for 15–20 minutes

    Moist heat sterilization in an autoclave operates with saturated steam at 121 °C under 15 pounds per square inch (psi / 103 kPa) above atmospheric pressure for at least 15 to 20 minutes. This achieves complete denaturation of proteins and thermal coagulation of all vegetative cells, viruses, and endospores.

    Show worked solution
    Step 1: Sterilization criteria: - Boiling (100 °C): kills vegetative cells but not resistant bacterial endospores. - Dry heat oven: 160-170 °C for 2 hours. - Pasteurization: 72 °C for 15 s (reduces pathogens, does not sterilize). - Autoclave standard: 121 °C at 15 psi steam for 15-20 min. Answer: 121 °C at 15 psi (103 kPa) pure steam pressure for 15–20 minutes.
    Modelled on: the A/L Biology examination pattern